AH Safety Engineering

Service detail

Fire protection concepts that hold up in the approval process.

We combine protection objectives, use, existing conditions and technical measures into a clear basis for decisions.

A firestop is checked using a measuring device and a test report.
Concept · Review · Verification02

From findings to a verifiable basis

Deviations are identified, measures are justified and responsibilities are made visible.

What the concept makes clear.

A fire protection concept sets out the specific use, the structural starting point and the relevant requirements. It not only describes measures but also justifies how the intended protection objectives can be achieved and later verified.

Contact fire protection experts

When a fire protection concept is necessary.

A fire protection concept becomes necessary when a project has to be assessed as a whole in terms of fire protection because of its size, use, construction method, risk to persons or deviations from standard requirements. For certain special buildings, OIB Guideline 2 requires a fire protection concept in accordance with the OIB guide “Deviations in fire protection and fire protection concepts”.

Whether this applies to your project should be clarified early in line with the planning and the approval strategy – late preparation often leads to redesigns. We prepare fire protection concepts for the following, among others:

  • New buildings, coordinated with architecture, building services and structural engineering
  • Existing buildings where earlier permits and later conversions meet
  • Renovations, complemented by appropriate renovation concepts
  • Listed buildings that need special solutions

Components of the evidence

  • Clearly record the starting situation, use and relevant hazards
  • Coordinate structural, technical and organisational measures
  • Clearly document deviations, compensatory measures and responsibilities
  • Structure documents for coordination, approval and later operation

What is regulated in the concept.

The concept brings together the initial situation, hazards, legal and planning principles as well as structural, system-based, organisational and defensive measures into a verifiable overall system. Among other things, it takes into account building use, fire hazards, fire compartments, escape and rescue routes, fire resistance, fire alarm and extinguishing systems, smoke extraction, firefighting water supply and the conditions for fire brigade operations.

Similarly, we consider the interactions between architecture, building services and operational organisation. In the end, authorities, planners, contractors and later operators must be able to clearly understand the intended measures.

The path to a reliable document

The specific depth depends on the project, use, and procedures. The following sequence illustrates the working principle, but does not replace a project-specific assessment.

  • Compile: Bring together existing data, plans, usage, and open issues
  • Assess: Classify requirements and deviations professionally
  • Design: Define measures, interfaces, and evidence
  • Support: Provide technical support for queries, submission and implementation

Legal framework in Austria.

Building law generally falls within the jurisdiction of the federal states. The OIB guidelines harmonise structural engineering requirements, but they do not apply automatically and simultaneously throughout Austria: the federal states adopt them through their own laws or regulations and can set transitional provisions, additions or deviations.

In addition, there are official decisions as well as project-specific standards and Technical Guidelines for Preventive Fire Protection (TRVB). Standards and TRVB are not automatically law, but can become binding through legislation, official decisions or contractual agreements. Which version applies is determined for each project based on location, use, type of procedure and date of approval.

When standard requirements do not fit.

For complex projects or deviations from standard requirements, engineering-based evidence, fire and smoke spread simulations or evacuation calculations may be required. International codes from ISO, NFPA or SFPE can be used additionally, provided their application is suitable for the project and agreed with the competent bodies.

A coherent overall concept can combine technical and structural measures in such a way that protection objectives are achieved economically. However, special solutions must be justified in a traceable way and coordinated with the relevant authorities. The focus is on safety and approvability, not on merely reducing individual measures.

Costs and duration.

The cost of a fire protection concept depends on the technical scope of work required. Decisive factors include building type and size, use and fire risk, the quality of the existing documentation, the number of deviations and the need for variants and coordination. Additional effort may arise from surveys of the existing building, simulations or engineering-based evidence.

Processing time also depends on project size, planning stage and coordination requirements. The more complete the basic information and the earlier the specialist planners are involved, the more efficiently the concept can be prepared. The actual price can only be determined after reviewing the project documents and defining the scope of services.

If something changes later.

A fire protection concept is a planning basis that accompanies the project and must be reviewed and updated in the event of significant changes. Changes to use, layout or technology must be checked to determine whether they affect the agreed protection objectives. AH Safety Engineering can seamlessly combine the concept, coordination with authorities and execution control.

Concept routes

The form of evidence follows the project.

Depending on the use, the existing building and the deviation, the focus can be normative, engineering-based or project-specific. The choice is professionally justified before work begins.

01

Normative evidence

Requirements are applied to the specific project in a structured way and documented so that they can be verified.

02

Engineering assessment

Deviations are evaluated in a comprehensible manner using recognized methods, calculations or simulations.

03

Project-specific combination

Normative foundations and in-depth evidence are combined so that the protection objective and feasibility match.

NEWSLETTER

Tips and news on fire protection and safety

Once a month: new expert articles, seminar dates and changes to standards and regulations.

I am interested in

You can withdraw your consent at any time – via the unsubscribe link in every email. Details in our privacy policy.