Fire protection covers all structural, system-based, organisational and firefighting measures to prevent fires and to limit their effects.

Workplace of a fire protection planner with a plan and building components.
Illustrative image (AI-generated)
Terms · Regulations · Practice

34 technical terms at a glance

From the fundamentals through regulations and classifications to simulations.

Terms and basics

Note on application: The regulations legally applicable at the project site, the approved project documents and the specific official decision are always decisive. Standards, TRVB and international regulations must be checked for each project with regard to edition, binding force and scope of application.

Contact fire protection experts

Basics

Fire protection

Fire protection covers all structural, system-based, organisational and firefighting measures to prevent fires and to limit their effects. The technical objective is to protect people and animals, to limit the spread of fire, to enable effective extinguishing and rescue operations and to preserve property, operational capability and the environment.

A basic distinction is made between structural, system-based and organisational fire protection. Structural measures concern, for example, fire compartments, fire resistance and escape routes. System-based fire protection includes fire alarm, extinguishing and smoke extraction systems. Organisational fire protection governs responsibilities, checks, instruction and behaviour in the event of a fire.

The measures required depend in particular on a building's use, type of construction, size and hazard level. What is decisive is the coordinated interaction of all measures throughout the entire life cycle of a building.

Fire protection in Austria

Fire protection assessment in Austria takes place at several regulatory levels. Particularly relevant are federal and provincial law, the OIB guidelines declared binding in the respective federal province, official decisions, and the standards and Technical Guidelines for Preventive Fire Protection (TRVB) applicable to the project. Which version applies must be established for each project on the basis of location, use, type of procedure and date of approval.

Building law generally falls within the competence of the federal provinces. The OIB guidelines were developed to harmonise building-related technical requirements. OIB Guideline 2 contains general requirements for fire protection. In addition, OIB Guideline 2.1 covers industrial buildings, OIB Guideline 2.2 garages, covered parking spaces and parking decks, and OIB Guideline 2.3 buildings with an escape level of more than 22 metres.

However, the OIB guidelines do not apply automatically and simultaneously throughout Austria. Each federal province adopts them through its own laws or ordinances and may lay down transitional provisions, additions or deviations. As a result, different editions and detailed requirements may be decisive depending on the federal province. Responsibilities, procedures and fire police provisions also differ in part. For every project it must therefore be checked which provincial regulations apply at the respective location.

In Carinthia, for example, the Carinthian Building Regulations (K-BV) and the Carinthian Building Technology Ordinance 2024 (K-BTV 2024) form the technical building framework. K-BTV 2024 refers to the OIB guidelines, May 2023 edition. In addition, the Carinthian Hazard and Fire Police Ordinance 2000 (K-GFPO) governs, among other things, fire prevention and the official fire inspection. Other federal provinces have their own building codes, building technology ordinances and fire police laws, whose content and names may differ from the Carinthian regulations.

In addition to provincial law, federal provisions must be taken into account. These include in particular the Austrian Trade Act (GewO) for commercial facilities, and the Employee Protection Act (ASchG), the Workplace Ordinance (AStV) and the Signage Ordinance for workplaces. These regulations apply throughout Austria, but in the specific project they are applied together with the respective provincial law and the conditions imposed by the authorities.

ÖNORM standards and European standards describe technical principles for planning, execution and testing. The Technical Guidelines for Preventive Fire Protection (TRVB) cover, among other things, fire alarm systems, organisational fire protection, self-inspections, fire plans and various special uses. Standards and TRVB are not automatically laws. However, they can become binding through legal provisions, official decisions, contractual agreements or as a specification of the state of the art.

For international or particularly complex projects, regulations and engineering methods from ISO, NFPA or SFPE can be used in addition. They do not replace Austrian and province-specific regulations, but can form an important technical basis for special solutions, performance-based evidence or international project requirements.

Safety technology

Safety technology refers to the coordinated system of technical installations for hazard detection, alarm, control and damage limitation. In the operation of buildings and installations, it includes in particular fire detection, voice alarm, emergency lighting, smoke control, extinguishing technology and the associated power supplies, wiring systems and interfaces.

A safety system does not consist of individual devices alone. Power supply, wiring, control, interfaces, monitoring and regular maintenance are equally important. The design depends on the existing hazards, the use of the building, the number and protection needs of the persons present and the operational processes.

Depending on the installation, different legal, official and normative requirements apply to planning, installation and operation. In addition to Austrian and European regulations, ISO or NFPA regulations may also be relevant for international projects. These must always be checked for applicability in the specific project.

Fire protection technology

Fire protection technology comprises systems and equipment that detect fire parameters, alert people, limit fire or smoke and support or automatically initiate extinguishing measures. It must be functionally integrated into the fire protection concept and coordinated with structural and organisational measures.

The most important systems include fire alarm and alerting systems, automatic sprinkler and extinguishing systems, smoke and heat extraction systems, pressurisation systems, firefighting water installations, and safety and emergency lighting. Fire event controls, for example for lifts, ventilation systems or fire-rated closures, are also included.

The fire protection technology required results from the fire protection concept, the legal and official requirements, and the use and hazard level of the building. For reliable operation, the systems must be coordinated with one another, professionally installed, regularly inspected and properly maintained.

Preventive fire protection

Preventive fire protection covers all protective measures planned and kept effective before a fire event. It is divided into structural, system-based and organisational fire protection; its design depends on use, fire hazard, occupancy and the defined protection objectives.

It is divided into three areas: structural fire protection concerns the construction and spatial subdivision of a building. System-based fire protection includes, for example, fire alarm, alerting, extinguishing and smoke extraction systems. Organisational fire protection governs responsibilities, checks, instruction and operational procedures.

This must be distinguished from defensive fire protection, which includes in particular the measures taken by the fire brigade and other emergency services during and after a fire event. Preventive and defensive fire protection must be coordinated so that access routes for the emergency services, firefighting water supply and technical installations can be used effectively in the event of an incident.

Structural fire protection

Structural fire protection defines the structural and spatial conditions intended to ensure load-bearing capacity, integrity, limitation of fire spread and safe escape routes and firefighting access routes for the required duration.

These include fire-resistant walls, ceilings and load-bearing structures, the formation of fire and smoke compartments, fire-rated closures and professionally executed firestops for service and ventilation penetrations. The location, length and structural design of escape and rescue routes are also an essential component.

The requirements depend, among other things, on building class, use, size, occupancy and fire hazard. In Austria, the building regulations of the federal provinces and the OIB guidelines applicable in each case form an essential basis. In the event of deviations from standard requirements, evidence may be required that an equivalent level of protection is achieved through alternative measures.

System-based fire protection

System-based fire protection includes fixed technical systems for detection, alarm, fire event control, smoke control and firefighting. The required systems and levels of availability result from the use, the risk profile, the fire protection concept and the legally binding project basis.

Fire alarm systems detect fire parameters such as smoke, heat or flames and trigger defined alarm and control processes. Sprinkler systems and other extinguishing systems can automatically control or extinguish a fire. Smoke and heat extraction systems and pressurisation systems help to keep escape routes and firefighting access routes as low in smoke as possible. Emergency lighting makes orientation easier if the general lighting fails.

Reliable operation requires professional planning, coordinated interfaces, a suitable power supply and regular inspection and maintenance measures. The technical systems must also be consistent with the fire protection concept and the operational procedures.

Organisational fire protection

Organisational fire protection governs responsibilities, operational procedures and control measures that reduce fire hazards and ensure that structural and technical protective measures remain functional during operation. It must be continuously adapted to changes in use, personnel, the building and the installed systems.

Typical components include site-specific fire safety regulations, clearly defined responsibilities, regular self-inspections, keeping a fire safety log as well as instructions and evacuation drills. Depending on official or statutory requirements, fire safety officers, fire wardens or other responsible persons may have to be appointed.

In Austria, TRVB 119 O on organisational fire protection, TRVB 120 O on self-inspection and TRVB 117 O on training in particular contain important technical foundations. In addition, workplace law, official conditions and building-specific requirements, among other things, must be observed. Organisational measures must be reviewed regularly and adapted in the event of changes in use, personnel, the building or technology.

Concept and planning

Fire protection concept

A fire protection concept is the overall presentation, oriented towards protection objectives, of the fire protection measures planned for a building or installation. It brings together the initial situation, hazards, legal and planning bases, and structural, system-based, organisational and firefighting measures into a verifiable overall system.

The concept takes into account, among other things, building use, fire hazards, fire compartments, escape and rescue routes, fire resistance, fire alarm and extinguishing systems, smoke extraction, firefighting water supply and the conditions for fire brigade operations. Interactions between architecture, building services and operational organisation are also considered.

In Austria, the OIB guide “Deviations in fire protection and fire protection concepts” in particular forms an important basis. For complex projects or deviations from standard requirements, engineering-based evidence, fire and smoke spread simulations or evacuation calculations may be required. A fire protection concept is to be understood as a planning basis accompanying the project and must be reviewed or updated in the event of significant changes.

Creating a fire protection concept

Creating a fire protection concept is an interdisciplinary engineering service. It comprises establishing the basic information, analysing risks and protection objectives, defining the required protective measures, coordinating interfaces and documenting the chosen solution in a comprehensible way.

The process begins with recording the building data, analysing the use and identifying possible fire hazards and hazards to persons. The protection objectives are then defined and suitable structural, system-based and organisational measures are developed. These are coordinated with the architecture, building services, structural design and operational requirements.

For special buildings or significant deviations, additional calculations and simulations may be necessary. The finished concept must be structured in such a way that authorities, planners, contractors and subsequent operators can clearly understand the intended measures. Changes during planning and execution must be checked for their impact on the overall concept.

Fire protection concept costs

The cost of a fire protection concept results from the technically required scope of work. The decisive factors are in particular the type and size of the building, its use and fire hazard, the quality of the documents on the existing building, the number of deviations, the need for variants and coordination and any engineering methods or simulations that may be required.

For standard buildings, it is often possible to rely on clearly defined requirements. Special buildings, existing buildings or significant deviations from building law requirements, on the other hand, usually call for more in-depth work. Additional costs may arise from surveys of the existing building, studies of variants, fire and evacuation simulations or the preparation of engineering evidence.

Creating the concept at an early stage can reduce the overall planning effort. Fire protection requirements can then be taken into account before the architecture, building services and construction have largely been finalised. The specific price can only be determined after the project basis has been reviewed and the required scope of services has been defined.

Fire protection planning

Fire protection planning is the systematic conversion of legal, technical and project-specific fire protection requirements into solutions that are suitable for approval, tender and execution. It expediently begins at the preliminary planning stage and continues up to commissioning and as-built documentation.

Planning content includes, for example, building class, fire compartments, fire resistance, escape routes, firefighting water supply and the necessary technical fire protection systems. At the same time, interfaces with architecture, the load-bearing structure, ventilation, electrical engineering and operational organisation must be taken into account.

Planning is based on legal provisions, OIB guidelines, standards, TRVB, official requirements and project-specific protection objectives. Additional regulations may apply to international projects. Continuous fire protection planning makes it easier to coordinate those involved and ensures that the intended measures are implemented consistently in tendering, execution and documentation.

Fire plan

A fire plan is a standardised tactical command tool for fire brigade operations. It shows only operationally relevant information about the building in a graphic form that can be grasped quickly, and must be clearly distinguished from escape route plans and orientation plans for building users.

It shows, among other things, building entrances, fire brigade access roads, set-up and movement areas, fire compartments, firefighting access routes, firefighting water supply, fire alarm and extinguishing systems and areas with particular hazards. The presentation must be clear, up to date and quick to grasp even under operational conditions.

In Austria, fire plans are prepared in accordance with TRVB 121 O “Fire plans for fire brigade operations” in the version currently in force. Requirements of the locally competent fire brigade or authority may also apply. In the event of structural, technical or operational changes, it must be checked whether the fire plan needs to be updated.

Creating a fire plan

Creating a fire plan begins with collecting and verifying all operationally relevant information about the building. Building plans and site plans must be compared with the actual situation on site by means of a walk-through and then prepared in accordance with TRVB 121 O and any regional requirements.

The operationally relevant information is then presented in site plans and floor plans in accordance with TRVB 121 O. This includes uniform colours, plan symbols, designations and organisational structures. Depending on the building, overview plans, detailed plans or additional technical fire protection descriptions may be required.

Before completion, the plan is usually coordinated with the competent fire brigade or the designated endorsement body. Regional requirements can affect the scope and the number of copies needed. Since a fire plan must reflect the actual condition of the building, it must be reviewed after conversions, changes of use or changes to technical systems and reissued if necessary.

Escape route plan

An escape route plan is a location-specific orientation plan for building users. It shows the course of the available escape routes, emergency exits and assembly points as well as selected facilities for alerting, first aid and initial firefighting in a uniform, easy-to-grasp presentation.

In addition to the escape direction and assembly point, fire extinguishers, fire detectors, first aid facilities and other safety equipment can be shown. The plan must be aligned to its location, mounted in a clearly visible position and easy to understand even for people unfamiliar with the site.

ISO 23601 is used for design and layout. The safety signs used in it are based in particular on ÖNORM EN ISO 7010. In Austrian workplaces, the Workplace Ordinance (AStV) and the Signage Ordinance must also be observed. An escape route plan must be distinguished from the fire plan according to TRVB 121 O: the escape route plan is aimed at building users, the fire plan primarily at the fire brigade.

Buildings and uses

Fire protection in special buildings

Because of their use, dimensions, type of construction, occupancy or operational hazards, special buildings have a risk profile that differs from that of standard buildings. The required fire protection must therefore be designed specifically for the building and with a focus on protection objectives; purely tabular standard requirements are often not sufficient for this.

Standardised requirements are often not sufficient for such buildings or cannot be applied in full because of the intended use. An individual assessment of the fire hazards, evacuation conditions and options for emergency response is therefore required.

OIB Guideline 2 requires a fire protection concept for certain special buildings in accordance with the OIB guidance document “Deviations in Fire Protection and Fire Protection Concepts”. In addition to structural, system-based and organisational measures, engineering methods can be used. These include fire and smoke spread simulations, evacuation calculations, risk assessments and performance-based evidence. International regulations from ISO, NFPA or SFPE can be used as a supplement, provided that their application is suitable for the project and has been agreed with the competent bodies.

Building classes 1 to 5

In the OIB definitions, building classes GK 1 to GK 5 form the basis for graduated technical building requirements. The classification is based on the escape level, the number of above-ground storeys, the gross floor area, access and the division into flats or business units.

The escape level is the difference in height between the top of the floor of the highest above-ground storey and the lowest point of the adjacent ground after completion.

Building class 1 – GK 1

GK 1 comprises detached buildings with no more than three above-ground storeys that are accessible from outside on at least three sides for firefighting. The escape level may be no more than 7 m and the total gross floor area of the above-ground storeys no more than 400 m². A maximum of two flats or one business unit is permitted.

Building class 2 – GK 2

GK 2 comprises several building variants with no more than three above-ground storeys and an escape level of no more than 7 m. These include buildings with a total gross floor area of no more than 400 m², certain terraced houses with usage units of no more than 400 m² each, and detached residential buildings with good external access and a total gross floor area of no more than 800 m².

Building class 3 – GK 3

GK 3 comprises buildings with no more than three above-ground storeys and an escape level of no more than 7 m which, because of their size, layout or use, do not meet the conditions of GK 1 or GK 2.

Building class 4 – GK 4

GK 4 comprises buildings with no more than four above-ground storeys and an escape level of no more than 11 m. Where there are several flats or business units, the usable floor area of each individual unit may be no more than 400 m². If the building consists of only one flat or one business unit, its gross floor area is not limited by this definition.

Building class 5 – GK 5

GK 5 comprises buildings with an escape level of no more than 22 m that cannot be assigned to building classes 1 to 4. Buildings with an escape level of more than 22 m are dealt with separately under OIB Guideline 2.3.

The building class influences, among other things, the requirements for the load-bearing structure, the fire resistance of building components, fire compartments, façades, escape routes and technical fire protection installations. Which OIB edition is to be applied depends on the provincial provisions and the specific approval procedure.

Large garages

The term “large garage” is a common collective term, but in the current OIB system it is not a uniformly defined building category. The fire protection requirements are graduated according to usable floor area, number of storeys, position relative to ground level, type of construction and technical equipment.

The essential basis for fire protection is OIB Guideline 2.2 “Fire protection in garages, covered parking spaces and parking decks”. It contains graduated requirements for garages of different sizes. Since the OIB guidelines are adopted into their legal systems by the individual federal provinces, it must be checked which edition is legally applicable at the respective project location and whether there are any provincial additions or deviations.

Increased requirements for building components, fire compartments, escape routes, emergency lighting and smoke and heat extraction apply to garages with more than 250 m² of usable floor area. In principle, a direct exit to the outside or a suitable escape route must be reachable from every point in a garage within a walking distance of no more than 40 metres. Depending on size, number of storeys and location, two mutually independent escape routes may be required. Garages with more than 250 m² of usable floor area must also be provided with emergency lighting, the extent of which depends on the size of the garage.

In multi-storey garages with a total usable floor area of more than 600 m², each storey must in principle be formed as a separate fire compartment. In garages of this size, connections to corridors or stairwells may in principle only be made via appropriately constructed and effectively ventilated airlocks. The permissible size and longitudinal extent of the fire compartments depend, among other things, on whether smoke and heat extraction installations, fire alarm systems or automatic extinguishing systems are present.

For initial firefighting, OIB Guideline 2.2 requires a suitable portable fire extinguisher to be kept ready at an easily accessible location for every 200 m² of usable floor area or part thereof. Special requirements apply to extended firefighting aid: in garages with more than 1,600 m² of usable floor area, with more than two underground storeys or with more than three above-ground storeys, wall hydrants with a dimensionally stable D hose and a suitable connection for the fire brigade are required in principle. They must be arranged so that every point in the garage can be reached with firefighting water. In single-storey garages with more than 1,600 m², a dry riser with hose connections inside the garage may be sufficient instead of wall hydrants, subject to the conditions of OIB Guideline 2.2.

The planning, execution, inspection and maintenance of dry, wet and wet-dry firefighting water systems and of wall hydrants are governed in more detail in TRVB 128 S “Fixed extinguishing systems, wet and dry”. Dry firefighting water pipes are fed by the fire brigade during an operation and serve exclusively for fire brigade use. Wet firefighting water systems are permanently under water pressure. Depending on their design, wall hydrants connected to them may be intended for initial or extended firefighting and to support the fire brigade. In addition, TRVB 124 F “Initial and extended firefighting” deals with the selection, number and arrangement of firefighting equipment and firefighting water systems.

Depending on the fire protection concept and official requirements, further TRVB may have to be applied. TRVB 123 S is particularly relevant for fire alarm systems, TRVB 125 S for smoke and heat extraction systems and TRVB 127 S for sprinkler systems. Fire plans for fire brigade operations are prepared in accordance with TRVB 121 O. The in-house fire protection organisation and regular self-inspections may be based on TRVB 119 O and TRVB 120 O. TRVB 134 F on areas for the fire brigade may also be important for access roads, set-up areas and movement areas.

Expert reports, inspection and renovation

Fire protection report

A fire protection report is a comprehensibly reasoned expert assessment of an established or planned condition or of a clearly formulated fire protection question. It separates findings, assessment criteria and conclusion and must be verifiable by competent third parties.

Fire protection reports are needed, for example, in building procedures, commercial facility permit procedures, changes of use, conversions or the assessment of existing buildings. Deviations from building law requirements, special uses, special buildings or differing views on the necessary fire protection measures can also be grounds for a report. The competent authority may call in an official expert for this purpose or require the submission of an expert assessment. A report commissioned by the project side is usually referred to as a private expert report.

What does a fire protection report contain?

The exact content depends on the task. The report usually begins with findings that objectively describe the building, its use and the existing or planned condition. These include, among other things, building dimensions, building class, escape level, fire compartments, building materials and components used, escape and rescue routes and existing fire protection installations.

This is followed by the expert assessment. The established facts are compared with the applicable laws, ordinances, standards, guidelines, permit decisions and recognised technical rules. Depending on the question, the following topics may be covered:

  • Reaction to fire of building materials and fire resistance of building components
  • Formation and separation of fire compartments
  • Execution of fire walls, fire doors and firestops
  • Length, width, and safe usability of escape routes
  • Smoke extraction and keeping areas free of smoke
  • Fire alarm, alerting and extinguishing systems
  • Firefighting water supply and accessibility for the fire brigade
  • Organisational fire protection measures
  • Effects of a deviation and possible compensatory measures

The report ends with a summarising conclusion. It answers the technical question posed and, where applicable, records which measures are required to achieve the intended level of protection.

Legal and normative foundations in Austria

Which provisions apply depends on the location, the use and the respective procedure. Austrian building law falls within the competence of the federal provinces. The building codes and building technology ordinances of the respective province therefore form an essential basis. The OIB guidelines declared binding in them specify the technical building requirements. For fire protection, OIB Guideline 2 in particular is relevant, as well as – depending on the building project – guidelines 2.1 for industrial buildings, 2.2 for garages, covered parking spaces and parking decks, and 2.3 for buildings with an escape level of more than 22 metres.

In addition, ÖNORM standards, European standards and the Technical Guidelines for Preventive Fire Protection, TRVB for short, may be used. These regulations are not always directly legally binding. However, their significance can arise from a statutory reference, an official decision, a contractual agreement, the state of the art or the specific technical task. In addition, federal law requirements, for example from trade law or employee protection law, may have to be taken into account.

For complex or performance-based evidence, fire protection engineering methods can also be used. These include, for example, fire and smoke simulations, evacuation calculations or computational analyses of structural behaviour in the event of fire. International standards and methods from ISO, NFPA or SFPE can provide additional foundations for this. In Austria, however, they are not automatically legally binding; their applicability and the assumptions used must be technically justified for the specific project and brought into line with the Austrian protection objectives.

Who is allowed to prepare a fire protection report?

The report should be prepared by a person who has the necessary training, authorisation and demonstrable expertise for the specific task. Depending on the procedure and the subject of the evidence, those who may be considered include in particular suitably authorised civil engineers (Zivil­techniker), engineering firms, generally sworn and court-certified experts, experts from fire prevention offices or official experts appointed by the authorities.

Not every technical statement on fire protection automatically has the status of an expert report. What matters is a clearly formulated task, a complete record of findings, the professional qualifications of the person preparing it and a coherent, verifiable derivation of the results. Whether a private expert report submitted in official proceedings is accepted as sufficient evidence is ultimately decided by the competent authority.

Difference between a fire protection report and a fire protection concept

A fire protection concept sets out all the planned structural, system-based, organisational and defensive fire protection measures for a project. It serves primarily for planning and describes how the relevant protection objectives are to be achieved.

A fire protection report, by contrast, assesses an established or planned condition or a specific technical question. It can review a fire protection concept, assess a deviation, examine the equivalence of a solution or assess the condition of an existing building. Depending on the task, the two document types can overlap in content; however, they do not necessarily serve the same purpose.

Furthermore, a fire protection report neither replaces an official permit nor automatically replaces all other required evidence. It provides a technical basis for decisions, while the legal assessment and the setting of any conditions lie with the competent authority.

Fire protection assessors

Fire protection assessors are specialists who investigate fire protection matters and assess them in writing. Since the title is not uniformly protected in Austria, expertise, professional authorisation, experience, independence and recognition in the procedure concerned must be checked in particular for the specific assignment.

Particularly eligible to prepare them are engineering firms – consulting engineers – with the corresponding specialist authorisation. Their statutory scope of activity expressly includes investigations, inspections, calculations and the preparation of expert reports in the relevant fields. Generally sworn and court-certified experts in the appropriate field, such as fire protection, also hold a particularly distinguished position.

Depending on the specific task, authorised civil engineers, official experts, specialists from fire prevention offices or other demonstrably qualified persons can also prepare reports. Whether a person is recognised for a particular fire protection report ultimately depends on the task, the scope of their authorisation and the requirements of the competent authority or court.

Fire protection experts

Fire protection experts assess technical matters of preventive and defensive fire protection on the basis of special expertise and practical experience. Their scope of work ranges from planning and assessment of the existing situation, through support during the approval and construction phases, to root cause analysis and the technical preservation of evidence.

Depending on their specialisation, they deal with structural, system-based or organisational fire protection. This includes, for example, fire compartments, fire resistance, escape and rescue routes, fire alarm systems, smoke extraction systems, extinguishing systems, firefighting water supply, fire brigade access and in-house fire protection organisation. Their tasks can also include inspecting measures that have been carried out, assessing existing buildings or providing technical support after a fire.

Qualification of a fire protection expert

In Austria, there is no single, generally prescribed training that automatically makes a person a fire protection expert in all areas. The qualification required depends on the task in question. A technical foundation is often provided by technical training in civil engineering, architecture, building services, safety engineering or a comparable field.

Added to this are several years of relevant professional experience and in-depth knowledge of the building codes and building technology ordinances of the federal provinces, the OIB guidelines, ÖNORM standards, European standards and the Technical Guidelines for Preventive Fire Protection. For complex tasks, knowledge of fire protection engineering and international methods, such as those of SFPE or NFPA, may also be required. These international sets of rules are not automatically legally binding in Austria, but can be used to supplement the technical assessment.

Individual courses or personal certificates can demonstrate specific knowledge. However, they do not automatically replace the required professional experience, a statutory professional authorisation or court certification.

Generally sworn and court-certified expert

This is a qualification regulated by law. The person concerned is entered in the Austrian list of court experts for a precisely defined field. In fire protection, the entry is made within the specialist and certification scope provided for this purpose.

Certification is carried out by the president of the competent regional court. Before entry in the list, extensive requirements must be met and the necessary knowledge must be demonstrated in a certification procedure. These include in particular:

  • special expertise in the field applied for
  • knowledge of procedural law and of the rules governing experts
  • ability to properly record findings
  • ability to formulate coherent and comprehensible conclusions
  • personal suitability and trustworthiness
  • sound financial circumstances
  • adequate technical and organisational resources
  • taking out the prescribed liability insurance

In principle, ten years of responsible work in the field applied for or a related field are required. With relevant university education or higher technical education, five years of professional work may be sufficient. Before entry in the list, an expert's oath is taken, which obliges the expert to investigate carefully, give a complete account of their observations and make an assessment to the best of their knowledge and conscience.

Court-certified experts must act independently, objectively and impartially. They support courts and authorities in answering specialist questions that lie outside general legal or administrative expertise. They can also be commissioned by companies, building owners, insurers or private clients. However, court certification does not automatically make a privately commissioned assessment a court expert report; this requires a specific appointment by the court.

Limited term and recertification

Entry in the list of court experts is initially for five years. It can then be extended by a further five years each time. For this recertification, the statutory requirements must continue to be met. In addition, the previous work as an expert and the further training completed must be set out.

The title “generally sworn and court-certified” therefore indicates verified expertise, practical experience and personal suitability. It must be distinguished from general course certificates or private certificates and may only be used within the scope of the field and certification actually entered in the list.

Fire protection construction supervision

Fire protection construction supervision monitors, within a defined scope of inspection, whether the planned and approved fire protection measures are implemented properly. Its focus is on critical interfaces, concealed systems, changes to plans and complete as-built documentation.

The supervision is based in particular on the approved fire protection concept, submission and construction plans, official decisions, the OIB guidelines applicable in the relevant federal province, relevant ÖNORM standards and TRVB, as well as classification reports, declarations of performance, approvals and manufacturers' installation specifications.

Tasks during construction

The exact scope is determined for each project. Fire protection construction supervision can include, among other things, the following activities:

  • checking the detailed design for conformity with the fire protection concept
  • coordination of fire protection interfaces between architecture, structural design, building services and the contractors
  • site inspections at defined construction phases
  • checking fire compartments and building components relevant to fire protection
  • support during the installation of fire protection cladding, fire-rated glazing and fire-rated closures
  • checking pipe and cable firestops
  • assessing the fire protection design of ventilation ducts and fire dampers
  • inspection of the arrangement and accessibility of escape and rescue routes
  • coordination of fire alarm, alerting, smoke extraction and extinguishing systems
  • recording and technical assessment of changes to plans
  • documentation of identified deviations and follow-up of their correction

Checks before closing shafts, wall linings, suspended ceilings or installation areas are particularly important. Once construction work is complete, many fire protection installations can no longer be inspected, or only with considerable effort.

Dealing with changes and deviations

During a construction project, room layouts, service routes, materials or technical systems often change. Such adjustments can have a direct impact on fire compartments, escape routes, fire resistance or the interaction of fire protection installations.

Fire protection construction supervision assesses these changes and compares them with the approved documents. Deviations are documented and, together with the designers, site management and contractors, brought to a suitable solution. Significant changes may require an adjustment of the fire protection concept, additional evidence or consultation with the competent authority.

Fire protection documentation

An essential component is the traceable documentation of the measures carried out. This can include site inspection reports, photographic records, lists of defects, product evidence, installation confirmations, markings and test reports. At the end of the project, the relevant documents are often brought together in final fire protection documentation.

Well-organised documentation makes later acceptance inspections, official procedures, recurring inspections and conversions easier. It also shows which systems and products were installed and under what conditions their fire protection performance has been demonstrated.

Fire load calculation

A fire load calculation quantifies the amount of heat theoretically releasable if the combustible materials considered burn completely. Expressed per unit of area, the result is given as the fire load density in MJ/m² and used as an input for fire protection assessments and design calculations.

The fire load is expressed in megajoules. When related to the floor area of the zone under investigation, it is referred to as the fire load density in megajoules per square metre – MJ/m². A high fire load can lead to more intense heat development, a longer fire duration and higher requirements for building components and fire protection installations.

How is the fire load calculated?

For the calculation, the combustible materials present, their mass and their calorific value are recorded. Variable fire loads include, for example:

  • Stored goods and packaging
  • Plastics, wood, paper and textiles
  • Flammable liquids
  • Furniture and furnishings
  • Cables
  • Production and auxiliary materials

In addition, permanently present fire loads from combustible building components, insulation materials, cables, floor constructions or permanently installed technical equipment can be taken into account. Depending on the calculation method, combustion factors, safety coefficients and use-specific parameters are also included.

The result must always be considered in the context of actual use. In addition to the fire load, room height, fire compartment area, type of storage, storage height, escape routes and the fire brigade's options for intervention are important, among other things.

Is a sprinkler system necessary?

A fire load calculation can be an important basis for deciding whether a sprinkler system or other fire protection installation is required. However, it does not decide this question alone. The decisive factor is an overall assessment of legal requirements, building type, use and actual fire risk.

For industrial and storage buildings, OIB Guideline 2.1 as applicable in the relevant federal province must be taken into account in particular. A sprinkler system may be required because of the use, may allow larger main fire compartments or may be used as a compensatory measure within a fire protection concept.

In Austria, TRVB 127 S is particularly relevant for the planning and design of sprinkler systems. In addition to the fire load, this takes into account the use, the fire hazard class, the type of stored goods and packaging, as well as the storage arrangement and storage height. A high fire load therefore does not automatically mean that any sprinkler system is suitable. The system must be planned and dimensioned according to the specific fire hazard.

Other applications

Fire load calculations can also be used for dimensioning smoke and heat extraction systems, determining firefighting water demand or for fire protection safety evidence. In fire protection engineering methods, the fire load can form a basis for fire and smoke simulations and for assessing the thermal stress on building components.

The calculation applies only to the assumed use and the defined storage conditions. If materials, storage quantities, storage heights or production processes change significantly, it must be checked whether the previous fire load calculation is still applicable.

Fire protection renovation

Fire protection renovation serves to specifically improve the fire protection of an existing building or commercial facility. This involves remedying identified defects, upgrading existing installations and adapting the fire protection measures to the actual use and the legally relevant requirements.

Renovation does not automatically mean that the entire building must be brought completely up to new-build standard. Which requirements apply depends on the lawfully existing building, the approval status, the nature and scope of the planned changes and the regulations of the relevant federal province.

When is renovation required?

A fire protection renovation may be prompted by inspections by the authorities, official fire inspections, recurring inspections of commercial facilities or technical surveys of the existing building. Conversions, extensions, changes of use and altered storage or production conditions can also make a new fire protection assessment necessary.

Typical renovation issues are:

  • missing or insufficient fire compartments
  • unsuitable or damaged fire-rated closures
  • defective pipe and cable firestops
  • insufficient escape and rescue routes
  • outdated fire alarm, alerting or extinguishing systems
  • missing or insufficient smoke extraction
  • increased fire loads
  • deviations from the approved condition
  • missing inspection, maintenance or existing-building records

Survey of the existing building and renovation concept

The first step is a fire protection survey of the existing building. This involves examining the building, its actual use, existing approvals, official decisions, plans and fire protection installations. It is then checked whether the actual condition corresponds to the lawfully existing building and the requirements relevant to the property.

On this basis, a renovation concept can be drawn up. It describes the deviations identified, the protection objectives to be achieved and the necessary structural, system-based or organisational measures. The work can be prioritised according to risk and urgency and divided into renovation phases coordinated over time.

In certain cases, structural measures can be supplemented or partially compensated for by other suitable measures. However, such a deviation is only justifiable if the required level of protection is demonstrated coherently and traceably and the solution is permissible in the procedure concerned or recognised by the competent authority.

What requirements apply to existing buildings?

Austrian building law falls within the competence of the federal provinces. The decisive factors are therefore the relevant building code, the building technology ordinance and the edition of the OIB guidelines declared binding there. In addition, permit decisions, ÖNORM standards, TRVB and provisions of trade law and employee protection law may have to be taken into account.

OIB guidelines 2, 2.1, 2.2 and 2.3, 2023 edition, each contain a provision for construction work on existing buildings. According to this, in the case of changes affecting existing parts of a structure, deviations from current requirements may be permissible if the original level of requirements of the lawfully existing building is not worsened. However, this provision only applies in conjunction with the implementation of the relevant OIB edition in provincial law.

This does not give rise to unrestricted grandfathering. Whether existing constructions are still permissible must be checked for the specific property. Unapproved alterations, a change of use or a deterioration in the previous safety level may make an adjustment necessary.

Special feature of commercial facilities

For approved commercial facilities, the authority can, under the special conditions of § 79 Abs. 3 GewO 1994, order the submission of a renovation concept. This concerns cases in which the necessary protection of the interests covered by the Austrian Trade Act could only be achieved through measures that would change the essential nature of the approved commercial facility.

This case, regulated by law, must be distinguished from a fire protection renovation that is voluntary, required under building law or carried out because of individual defects.

Renovation based on protection objectives

Properly planned renovation considers not only individual defects but also the interaction of all fire protection measures. This allows investments to be targeted and disproportionate or technically unsuitable individual measures to be avoided.

For complex existing buildings, recognised fire protection engineering methods can be used, such as fire and smoke simulations, evacuation calculations or computational evidence for building components. International standards and methods from SFPE or NFPA can be taken into account as a supplement if this is technically suitable for the project and aligned with the Austrian requirements and the competent bodies. This does not create any automatic legal obligation.

Implementation should be supported by specialists and documented in a traceable manner. Depending on the procedure, certain evidence, inspections, acceptance inspections or confirmations may also be mandatory.

Inspection engineers

Inspection engineers check, within a defined inspection assignment, that design and execution conform to the approval documents and technical requirements. The title, authorisation, independence and scope of inspection are not uniformly regulated in Austria and must be derived from the relevant provincial law or procedure.

The term “inspection engineer” is not uniformly regulated in Austria for all federal provinces and inspection tasks. Which qualification is required and which powers exist depends on the relevant provincial law, the official procedure, the type of facility and the specific inspection assignment.

Tasks in fire protection

Fire protection inspections can begin as early as the planning documents and extend throughout construction until completion. Typical activities are:

  • checking conformity with permit decisions and approved plans
  • checking building components relevant to fire protection
  • inspection of fire compartments and fire-rated closures
  • checking pipe and cable firestops
  • inspection of escape and rescue routes
  • checking the construction products used and the evidence of their usability
  • documentation of deviations and workmanship defects
  • checking that defects have been remedied
  • preparation of inspection reports and confirmations

Checks of building components that will later be concealed or no longer accessible are particularly important. These include, for example, firestops in shafts, fire protection cladding or connections within suspended ceilings.

Inspection engineer under the building code

An expressly statutory function exists, for example, in Vienna. Under § 127 of the Vienna Building Code, an inspection engineer must in principle be appointed for certain construction projects requiring a permit. Civil engineers (Zivil­techniker) or generally sworn and court-certified experts in the relevant field may act as inspection engineers there.

The inspection engineer must be independent of the building applicant and the responsible contractor. They carry out the statutory inspections and checks during construction and report any deviations found from the approved building plans to the building authority. The prescribed evidence of these inspections must be submitted with the notice of completion.

This Viennese rule cannot simply be applied to the whole of Austria. Other federal provinces have different titles, responsibilities and requirements for monitoring construction.

Inspection of fire protection systems

The work of an inspection engineer under building law must be distinguished from the inspection of special fire protection systems. Fire alarm systems, sprinkler systems, smoke and heat extraction systems, pressurisation systems or emergency lighting are each subject to their own technical regulations and inspection requirements.

Depending on the legal provision, official decision or applicable standard, an inspection by authorised specialists, civil engineers, engineering firms, court-certified experts or accredited inspection bodies may be required. General work as an inspection engineer therefore does not automatically entitle a person to carry out the acceptance inspection of every fire protection system.

Qualification and independence

An inspection engineer needs technical training appropriate to the task, relevant professional experience and precise knowledge of the applicable building regulations, OIB guidelines, ÖNORM standards, TRVB and approval documents. Traceable inspection documentation and the ability to assess deviations technically are equally important.

Depending on the procedure, special authorisations, court certification or accreditation may be required. In addition, independence rules may stipulate that design, execution and inspection must not be carried out by the same person or organisation.

Inspection engineers replace neither the responsibility of the designers and contractors nor, automatically, an official inspection. Their task is to independently check proper execution within the defined scope of inspection and authorisation and to document it in a traceable manner.

Regulations and organisation

TRVB

The Technical Guidelines for Preventive Fire Protection (TRVB) are application-related technical rules for the planning, execution, inspection, operation and maintenance of fire protection measures in Austria. Their specific binding force arises from a legal reference, an official decision, a contract or their classification as a recognised rule of technology.

The TRVB are drawn up in the relevant working group of the Austrian Federal Fire Brigade Association in cooperation with the Austrian fire prevention offices. Representatives of the provincial fire brigade associations, professional and company fire brigades and specialists from the fire prevention offices contribute to the work on the guidelines. The work is supported, among others, by observers from the Austrian Institute of Construction Engineering, Austrian Standards, the Austrian Electrotechnical Association and the Insurance Association.

Which areas do the TRVB regulate?

The guidelines cover various fields of expertise. The letters in the designation indicate the respective subject area:

  • B-TRVB: structural fire protection
  • S-TRVB: system-based fire protection
  • O-TRVB: organisational fire protection
  • F-TRVB: defensive fire protection and fire brigade matters

Well-known areas of application include fire alarm systems, sprinkler systems, smoke and heat extraction systems, risers, wall hydrants, fire plans, in-house fire protection organisations and firefighting water supply.

Examples of current guidelines are:

  • TRVB 108 B for possible designs of structural fire protection
  • TRVB 119 O for organisational fire protection
  • TRVB 120 O for in-house self-inspections
  • TRVB 121 O for fire plans for fire brigade operations
  • TRVB 123 S for fire alarm systems
  • TRVB 127 S for sprinkler systems
  • TRVB 128 S for fixed firefighting water systems, risers and wall hydrants
  • TRVB 137 F for determining firefighting water demand

The number identifies the subject area covered. The year given in addition indicates the edition. A designation such as “TRVB 127/26 S” therefore refers to TRVB number 127 from the 2026 edition in the field of system-based fire protection.

Are TRVB mandatory by law?

TRVB are not automatically laws or ordinances. According to the classification of the Austrian Federal Fire Brigade Association, they are not legally binding on their own, but generally represent recognised rules of technology and are regularly used by experts as a basis for assessment.

A TRVB can become binding in a specific case if it:

  • is expressly mentioned in a legal provision
  • is prescribed by an official decision
  • is part of an approved fire protection concept
  • has been contractually agreed
  • has been specified as the basis for planning, tendering or acceptance
  • must be complied with under an insurance agreement

Whether a particular TRVB is to be applied must therefore always be checked on the basis of the project concerned, the approval status and the requirements of the authorities.

Relationship to OIB guidelines and ÖNORM standards

The TRVB do not stand alone. Austrian fire protection law results from the interplay of the building regulations of the federal provinces, the OIB guidelines declared binding in each case, federal law provisions, ÖNORM standards, European standards, TRVB and official conditions.

The OIB guidelines primarily set out the construction-related protection objectives and basic requirements. TRVB often describe in more detail how certain fire protection measures can be planned, executed, inspected and operated. If a binding legal provision contains different requirements, it takes precedence over a purely technical guideline.

In international projects, rules such as NFPA standards or SFPE methods can also be applied. However, they do not automatically replace the Austrian requirements. If Austrian and international rules are combined, differences in protection objectives, design bases and inspection requirements must be clearly resolved.

Pay attention to the current edition

TRVB are continually revised, replaced or withdrawn. Older guidelines may therefore be technically outdated or conflict with newer legal requirements. What matters is not only the number of the guideline, but also its edition and the legal and planning status defined in the project.

Before applying a TRVB, it should therefore be checked in the current TRVB index which edition is valid. For installations that have already been approved, however, the edition specified in the original official decision, fire protection concept or contract may remain decisive. Changes or extensions must therefore always be assessed taking the approved existing situation into account.

OIB guidelines

The OIB guidelines are technical guidelines of the Austrian Institute of Construction Engineering. They serve to largely harmonise the construction requirements of Austria's nine federal provinces. They cover basic requirements for the safety, health, accessibility, sound insulation and energy efficiency of structures.

The OIB guidelines are divided into the following sections:

  • OIB Guideline 1: Mechanical strength and stability
  • OIB Guideline 2: Fire protection
  • OIB Guideline 3: Hygiene, health and environmental protection
  • OIB Guideline 4: Safety in use and accessibility
  • OIB Guideline 5: Sound insulation
  • OIB Guideline 6: Energy saving and thermal protection

In addition, there are definitions, guidance documents and a document listing the cited standards and technical rules. These supplementary documents are important for correctly classifying terms, evidence procedures and normative references.

Are the OIB guidelines binding throughout Austria?

Publication does not automatically make the OIB guidelines law applicable throughout Austria. Building law falls within the competence of the federal provinces. The provinces can declare individual editions of the OIB guidelines binding through their building acts or building technology ordinances and can also specify additions, exceptions or transitional provisions.

At any given time, therefore, different editions of the same OIB guideline may have to be applied in two federal provinces. For a specific construction project, the provincial law concerned, the OIB edition declared binding there and the date of submission or approval must always be checked. The latest published version is not automatically the legally decisive version.

Importance for planning and approval

The OIB guidelines describe the level of safety and performance that a building must achieve. They contain both specific requirements and options for alternative solutions. Individual requirements may be deviated from in accordance with the applicable provincial law if conclusive evidence is provided that an equivalent level of protection is achieved.

In planning, the guidelines serve, among other things, to define requirements for load-bearing structures, fire protection, escape routes, accessibility, noise protection and energy efficiency. They also form an essential basis for assessment by building authorities, planners and experts.

The OIB guidelines must be distinguished from ÖNORM standards and TRVB. ÖNORM standards and European standards often contain detailed technical rules and test procedures. TRVB deal with specific questions of preventive and defensive fire protection. Which of these sets of rules must also be applied follows from legal provisions, cross-references, official decisions, contracts and the specific state of the art.

OIB Guideline 2 – Fire protection

OIB Guideline 2 defines the fundamental structural fire protection requirements for buildings. It deals in particular with load-bearing capacity in the event of fire, limiting the spread of fire and smoke, the protection of neighbouring structures, escape and rescue, and the prerequisites for effective firefighting.

The requirements depend, among other things, on the building class, the escape level, the use, the size of the building and its position in relation to neighbouring plots. Topics covered include, for example:

  • Reaction to fire of building materials
  • Fire resistance of components
  • Fire compartments and separating components
  • Facades and roofs
  • Escape and rescue routes
  • Requirements for stairwells and corridors
  • Access for the fire brigade
  • Special uses and special buildings
  • Building works on existing buildings

The general OIB Guideline 2 is supplemented by three specific guidelines. These are often referred to as subcategories, but are formally independent guidelines for particular building types and risk situations.

OIB Guideline 2.1 – Fire protection in industrial buildings

OIB Guideline 2.1 applies to industrial buildings used for the production or storage of products and goods. This may also include directly associated administrative, welfare and ancillary rooms. Retail premises, hospitality businesses and purely office buildings, by contrast, are not regarded as industrial buildings within the meaning of this guideline solely because of their business use.

The guideline deals in particular with:

  • Permissible sizes of main fire compartments
  • Requirements for load-bearing components and components forming fire compartments
  • Smoke and heat extraction
  • Fire alarm and extinguishing systems
  • Warehouse buildings and storage areas in production rooms
  • Categories of stored goods
  • Access and firefighting water supply
  • Cases in which a fire protection concept is required

The size, height and use of the industrial building, as well as existing fire protection systems, influence the permissible main fire compartment areas. Automatic fire alarm or sprinkler systems can lead to a higher safety category and, under defined conditions, to larger permissible areas.

OIB Guideline 2.2 – Fire protection in garages, covered parking spaces and parking decks

OIB Guideline 2.2 contains special requirements for garages, covered parking spaces and parking decks. The required level of protection depends, among other things, on the usable floor area, the location above or below ground level, the number of storeys and the type of construction.

In particular, the following are regulated:

  • Formation of fire compartments
  • Natural or mechanical ventilation
  • Emergency lighting
  • Fire extinguishers and wall hydrants
  • Risers and equipment for the fire brigade
  • Fire alarm and sprinkler systems
  • Special garage designs and automatic parking systems

A fire protection concept may be required for certain large garages, high parking decks, special garage types and areas for vehicles with special drive systems.

OIB Guideline 2.3 – Buildings with an escape level of more than 22 metres

OIB Guideline 2.3 applies to buildings with an escape level of more than 22 metres. As building height increases, escape, rescue and firefighting become more difficult. Higher requirements therefore apply compared with lower buildings.

The guideline distinguishes in particular between buildings with an escape level:

  • of more than 22 metres and up to a maximum of 32 metres
  • of more than 32 metres and up to a maximum of 90 metres
  • of more than 90 metres

Topics covered include increased requirements for building materials and components, fire compartments, safety stairwells, pressurisation systems, firefighters’ lifts, safety power supply, fire alarm systems and automatic extinguishing systems. For buildings with an escape level of more than 90 metres, a fire protection concept is required in any case.

OIB guide on deviations and fire protection concepts

The family of guidelines also includes the guide “Deviations in fire protection and fire protection concepts”. It is not a further subcategory like OIB Guidelines 2.1 to 2.3, but describes how to deal with deviations and how to prepare fire protection concepts.

In the case of significant deviations, the requirements concerned, the compensatory measures envisaged and the equivalence of the level of protection achieved must be presented in a comprehensible manner. For complex projects, recognised fire protection engineering methods may also be required for this purpose.

Which edition of OIB Guidelines 2, 2.1, 2.2 and 2.3 is to be applied depends on their implementation in the respective federal province. In addition, provincial law, official conditions, ÖNORM standards and TRVB can lay down further requirements.

Fire safety regulations

Fire safety regulations are the building-specific operational rules for fire prevention and for conduct in the event of fire. They set out responsibilities, inspection duties, alarm and evacuation procedures, and instructions for normal operation and in the event of a malfunction.

A general standard template is not sufficient for this purpose. The fire safety regulations must suit the actual use, the organisation of the building, the existing hazards and the technical fire protection equipment.

What do fire safety regulations contain?

The exact scope depends on the size and complexity of the building. Typical contents are:

  • Scope and description of the building
  • Responsibilities within the fire protection organisation
  • Tasks of fire safety officers and fire wardens
  • Rules for keeping escape routes and emergency exits clear
  • Regulations on the storage and handling of combustible substances
  • Smoking bans and rules on open flames
  • Authorisation and supervision of hot work
  • Conduct in the event of failure of a fire protection device
  • Alerting the fire brigade and internal reporting channels
  • Conduct on discovering a fire and on activation of an alarm
  • Evacuation, assembly points and support for persons requiring assistance
  • Use of fire extinguishers and other means of initial firefighting
  • Measures to prepare for and support the fire brigade’s response
  • Carrying out self-inspections, instruction sessions and drills

In larger or complex commercial facilities, the fire safety regulations can be structured in several parts. In addition to a general section for all persons present, there may be special instructions for fire safety personnel, managers, technical services or individual hazard areas.

When are fire safety regulations required?

An obligation may arise from the Employee Protection Act (ASchG), provincial legislation, a permit decision, the fire protection concept or other binding project documents.

Under § 45 of the Workplace Ordinance (AStV), fire safety regulations must be drawn up in particular in the context of enhanced fire protection, for example where a fire safety officer has been prescribed by the authorities or appointed under provincial provisions, or where a company fire brigade has been established. In these cases, the fire safety regulations must be brought to the attention of all employees and form part of the safety and health protection document.

Not every small business needs fire safety regulations under § 45 AStV simply because it exists. Whether there is an obligation must be checked on the basis of the use, the operational hazards, official conditions and the applicable legal provisions. Even without an express obligation, fire safety regulations can be useful for laying down responsibilities and rules of conduct in a binding manner.

Who draws up the fire safety regulations?

Responsibility for a proper in-house fire protection organisation lies, in principle, with the employer or operator. In practice, the regulations are often drawn up together with the fire safety officer or a suitably qualified person.

Drawing them up requires detailed knowledge of the building, the operational processes, the fire hazards and the existing fire protection equipment. For larger or technically complex facilities, the fire safety regulations should be coordinated with fire protection planning, building services, safety specialists and, where applicable, the fire brigade.

In Austria, the technical basis is in particular TRVB 119 O “Organisational fire protection”. It contains different templates for businesses without technical fire protection equipment, buildings with such equipment and complex commercial facilities. The TRVB must be considered together with the statutory requirements and the project-specific conditions in the official decision.

Communication and updating

Fire safety regulations are only effective if the persons concerned know their essential contents. New employees must therefore be informed of the fire safety rules, alarm routes, escape routes and assembly points applicable to them. Merely filing the document is not sufficient.

Where § 45 AStV applies, the fire safety regulations must be reviewed annually for accuracy and completeness and supplemented if necessary. Irrespective of this, they must be adapted if, for example, the following change:

  • Use or room layout
  • Escape and rescue routes
  • Contact persons or responsibilities
  • Alarm and evacuation organisation
  • Production and storage conditions
  • Technical fire protection equipment
  • Official conditions

Distinction from other fire protection documents

Fire safety regulations are not the same as a fire protection concept or a fire plan. A fire protection concept specifies the structural, system-based, organisational and firefighting measures by which the protection goals of a building are achieved. A fire plan presents the information essential for the fire brigade’s response in graphic form.

Fire safety regulations, by contrast, mainly govern the organisation of day-to-day operations and the conduct of persons. They turn technical and legal requirements into specific, understandable instructions for everyday use and for the event of fire.

Building components and classifications

Fire compartment

A fire compartment is an area separated from adjoining parts of the building in terms of fire protection. Walls, floors, closures and firestops forming a fire compartment must, as a continuous system, ensure the required integrity and, where applicable, load-bearing capacity and thermal insulation for the specified duration.

The purpose of this subdivision is to confine a fire to the affected area for as long as possible. This provides additional time for the escape and rescue of people, better conditions for the fire brigade’s response and effective protection of adjoining parts of the building.

How is a fire compartment formed?

The boundary is formed by components that create fire compartments. These include in particular:

  • Walls forming fire compartments
  • Floors forming fire compartments
  • Fire-rated closures such as fire doors and fire gates
  • Tested firestops for cables and pipes
  • Fire dampers in ventilation ducts
  • Suitable connections at facades and roofs

In principle, the separation must be continuously effective. A wall alone therefore does not yet form a functional fire compartment if it contains unprotected doors, service penetrations or other openings. Connections to floors, facades and roofs must also be designed so that a fire cannot simply bypass the separation.

What does the fire resistance class mean?

Components forming fire compartments must have the fire resistance required for the building. Designations such as EI 30, EI 60 or REI 90 indicate which properties a component must fulfil in the event of fire and for how long:

  • R: Load-bearing capacity
  • E: Integrity
  • I: Thermal insulation
  • 30, 60 or 90: Verified fire resistance duration in minutes

A load-bearing wall forming a fire compartment may, for example, require class REI 90. For a non-load-bearing wall, an EI 90 classification may be sufficient. The specific requirement depends on the building class, use, location and the applicable set of rules.

How large may a fire compartment be?

The permissible size of a fire compartment is not laid down in general terms, but depends on several factors. These include in particular:

  • Type of use
  • Building class and building height
  • Above-ground or below-ground location
  • Number of storeys
  • Existing fire alarm or extinguishing systems
  • Fire hazards and storage conditions
  • Special requirements for industrial buildings, garages or special buildings

For general buildings, OIB Guideline 2 contains corresponding requirements. Industrial buildings are assessed in particular under OIB Guideline 2.1, garages and parking decks under OIB Guideline 2.2 and buildings with an escape level of more than 22 metres under OIB Guideline 2.3. The edition legally applicable in the respective federal province is decisive.

Not every room is a separate fire compartment

A fire compartment may consist of a single room, several rooms or – depending on the permissible limits – several storeys. Conversely, not every partition wall between two rooms automatically constitutes a fire compartment boundary.

Fire compartments must also be distinguished from smoke compartments. A smoke compartment is primarily intended to limit the spread of smoke and does not necessarily have to meet the same fire resistance requirements as a fire compartment.

For industrial buildings, the term “main fire compartment” is also used. According to the OIB definitions, this refers to an area separated from other parts of a building by fire walls.

Relevance during ongoing operation

The effectiveness of a fire compartment must be maintained throughout its entire service life. Subsequently installed services, improperly sealed penetrations, damaged fire doors or fire-rated closures that are permanently held open can significantly impair the protective effect.

Fire compartment boundaries must therefore be taken into account during conversions and installation work and checked as part of the scheduled inspections. Changes should be documented in a traceable manner and updated in fire plans and other affected documents.

Fire resistance classes

Fire resistance classes describe the duration, proven under standardised test conditions, during which a component meets defined performance criteria. The classification combines criteria such as R, E and I with a time in minutes; it is not a forecast of the actual resistance time in any given real fire.

The classification consists of letters for the proven performance characteristics and a time in minutes. REI 90, for example, means that the tested component has maintained its load-bearing capacity, integrity and thermal insulation for at least 90 minutes under the relevant standard fire exposure.

This time cannot be equated with a guaranteed resistance time in every real fire. Actual fires may develop differently from the standardised fire resistance test owing to the fire load, ventilation, room geometry and existing extinguishing measures.

The most important performance criteria

  • R – Load-bearing capacity: The component retains its load-bearing function.
  • E – Integrity: Flames and hot gases do not penetrate to an impermissible extent to the side facing away from the fire.
  • I – Thermal insulation: The temperature on the side facing away from the fire remains within specified limits.
  • W – Limitation of heat radiation: The heat radiation passing through the component remains below the specified limit value.
  • M – Resistance to mechanical stress: The component withstands additional impact loading, for example from components or stored goods falling over in the event of fire.
  • C – Self-closing property: A movable fire-rated closure closes automatically.
  • S – Limitation of smoke leakage: The component or system meets specified requirements for smoke tightness.

Further designations exist for special construction products and systems:

  • P: Maintenance of power or signal supply under the standard fire curve
  • PH: Maintenance of function of power or signal cables under a specified constant temperature exposure
  • G: Soot fire resistance of a flue system
  • O: Flue system without proven soot fire resistance
  • K: Fire protection effect of a wall or ceiling lining
  • T: Temperature class for flue systems
  • D: Stability duration at constant temperature
  • DH: Stability duration under the standard fire curve
  • F: Function of powered smoke and heat extraction devices
  • B: Function of natural smoke and heat extraction devices

Not every criterion is intended for every construction product. Which letters and combinations are used depends on the function and the applicable test and classification procedure.

Common time classes

Depending on the type of component or system, the following classification times may occur:

10, 15, 20, 30, 45, 60, 90, 120, 180, 240 or 360 minutes

Not every time level is available for every product group or relevant under building law. In Austrian building practice, requirements of 30, 60 and 90 minutes are particularly common.

Typical fire resistance classes

R 30, R 60, R 90

These classes are used for load-bearing components without a separating function, for example columns or beams. R 90 means that the load-bearing capacity has been proven for at least 90 minutes.

REI 30, REI 60, REI 90, REI 120

This combination applies to components that are both load-bearing and separating, such as load-bearing walls or floors forming fire compartments. All three criteria must be met for the stated duration.

EI 30, EI 60, EI 90, EI 120

These classes apply to non-load-bearing separating components. Examples are non-load-bearing fire protection walls, glazing, installation shafts and firestops.

E 30, E 60, E 90

Here, only integrity has been proven. Sufficient limitation of the temperature on the side facing away from the fire is not part of the classification.

EW 30, EW 60, EW 90

In addition to integrity, heat radiation is limited. However, the thermal insulation requirements of an EI classification are not fully met.

REI-M 60, REI-M 90

In addition to load-bearing capacity, integrity and thermal insulation, resistance to mechanical impact loading has also been proven. Criterion M may be required, for example, for fire walls or walls forming fire compartments that may be exposed to mechanical stress.

Fire doors and fire gates

For fire-rated closures, classes such as EI₂ 30-C, EI₂ 60-C or E 30-C are often used.

The suffix C denotes the self-closing property. Classes C0 to C5 describe the proven durability of self-closing on the basis of a certain number of test cycles.

For doors, a distinction is made between I₁ and I₂. Both denote thermal insulation criteria, but are based on different measurement and assessment conditions. EI₁ 30 and EI₂ 30, for example, must therefore not be regarded as equivalent without verification.

Smoke protection requirements may additionally be designated Sₐ or S₂₀₀:

  • Sₐ: Smoke tightness at ambient temperature
  • S₂₀₀: Smoke tightness also at an elevated test temperature of 200 °C

A designation such as EI₂ 30-C S₂₀₀ thus contains requirements for integrity, thermal insulation, automatic closing and smoke protection.

Other additional information

Fire resistance classes can be supplemented by information on the installation direction and fire exposure:

  • i → o: Exposure from inside to outside
  • o → i: Exposure from outside to inside
  • i ↔ o: Exposure from both directions
  • ve: Vertical installation position
  • ho: Horizontal installation position

Such information is important, for example, for installation shafts, ventilation ducts, fire dampers and firestops. A classification applies only to the tested or classified field of application.

Old Austrian designations

Designations such as F 30, F 60, F 90 or T 30 appear in older plans, official decisions and documents on existing buildings. These come from earlier national classification systems.

Old and European classes must not be equated across the board. Whether an earlier classification corresponds to a current requirement must be assessed on the basis of the component, the test basis at the time, available evidence and the current legal question.

What determines the required class?

  • The required fire resistance class results in particular from:
  • Building class and escape level
  • Use of the building
  • Position and function of the component
  • Formation of fire compartments
  • Above-ground or below-ground location
  • Special fire hazards
  • OIB guidelines and provincial law
  • Fire protection concept and official decision

The decisive factor is always the fully tested component or system. Individual materials must not be combined into a fire resistance class or subsequently altered without appropriate evidence.

Reaction-to-fire classes

Reaction-to-fire classes classify the contribution of a construction product to the development and spread of fire. Depending on the product group, the aspects assessed include ignitability, heat release, flame spread, smoke production and burning droplets or particles.

European classification is generally carried out in accordance with ÖNORM EN 13501-1. In Austria, reaction-to-fire classes are used in particular in OIB Guideline 2. Which class is required depends on the building class, the use and the position of the product in the building.

Reaction-to-fire classes A1 to F

A1 – No contribution to fire

Class A1 products make no contribution to fire under the specified test conditions. Typical examples may be concrete, brick, glass, natural stone or certain metals. However, the classification of the specific product is always decisive.

A2 – Very limited contribution to fire

Class A2 building materials may contain small combustible components, but contribute to fire only to a very limited extent. One example is class A2-s1,d0.

B – Very limited contribution to fire

Class B products show very favourable reaction to fire but do not reach the requirements of classes A1 or A2.

C – Limited contribution to fire

Class C products can make a limited contribution to fire. Their flame spread and heat release remain within specified limit values.

D – Acceptable contribution to fire

Class D products meet lower requirements than those of classes A to C. They can contribute more significantly to fire development and flame spread.

E – Limited resistance to a small flame

Class E only demonstrates a specified behaviour under brief exposure to a small flame. Further reaction to fire is assessed only to a limited extent.

F – Performance not determined or class E not achieved

Class F is used when there is insufficient evidence or the product does not meet the requirements of class E. It therefore does not necessarily denote a particular combustibility, but may also stand for an unclassified product.

The sequence A1 to F represents a gradation. A1 has the most favourable proven reaction to fire, while F does not confirm any sufficient classified performance.

Smoke production: s1 to s3

For classes A2 to D, reaction to fire is often supplemented by a smoke class. The letter “s” stands for “smoke”:

  • s1: Low smoke production
  • s2: Limited smoke production
  • s3: Higher smoke production or failure to comply with the limit values of s1 or s2

The smoke class is particularly important for escape and rescue routes. Dense smoke can restrict visibility, make orientation more difficult and pose a considerable danger because of the fire gases it contains.

Burning droplets: d0 to d2

The letter “d” stands for burning droplets or particles:

  • d0: No burning droplets or falling particles within the specified test period
  • d1: No burning droplets or particles that continue burning for longer than the specified duration
  • d2: Requirements of d0 or d1 are not met

Burning droplets can ignite materials underneath, promote the spread of fire and endanger people escaping.

Example A2-s1,d0

The classification A2-s1,d0 means:

  • Very limited contribution to fire
  • Low smoke production
  • No burning droplets or falling particles within the relevant test period

The main class and its suffixes must always be read together. A2-s1,d0 describes a better overall performance than, for example, C-s3,d2.

Special classes for floor coverings

Floor coverings are given the suffix “fl” for “flooring”. The possible main classes are:

  • A1fl
  • A2fl
  • Bfl
  • Cfl
  • Dfl
  • Efl
  • Ffl

Depending on the class, the additional assessment of smoke production s1 or s2 is added. A floor covering may, for example, be classified as Bfl-s1.

The floor class must not be equated with the normal building material class without the suffix “fl”, since different test procedures and assessment criteria apply.

Reaction to fire of cables

Separate classes with the suffix “ca” apply to electric cables:

  • Aca
  • B1ca
  • B2ca
  • Cca
  • Dca
  • Eca
  • Fca

In addition, cables can be assessed according to smoke production, burning droplets and the acid content or corrosivity of the fire gases:

  • s1 to s3: Smoke production
  • d0 to d2: Burning droplets and particles
  • a1 to a3: Acid content and corrosivity of the fire gases

A complete cable classification may, for example, read B2ca-s1,d1,a1.

Pipe insulation materials and insulation products

Thermal insulation products for linear pipes are marked with the suffix “L”. The classes range from A1L through A2L, BL, CL, DL and EL to FL. Depending on the main class, suffixes for smoke production and burning droplets may also be stated.

Roof coverings exposed to external fire

The behaviour of a roof covering when exposed to fire from outside is classified separately. A common designation is BROOF(t1). Here, “t1” denotes the test method applied and not an additional quality level.

In addition to BROOF, further classes up to FROOF may be used depending on the test method. This roof classification is not to be equated with the normal reaction-to-fire classes of wall or ceiling products.

Difference from fire resistance

Reaction to fire and fire resistance describe two different properties:

  • A1, A2, B, C, D, E and F describe the contribution of a building material or construction product to fire.
  • R, E, I and times such as 30, 60 or 90 minutes describe the fire resistance of a component or type of construction.

A component may have to meet both requirements. The specification REI 90 and A2 means, for example, that the component must demonstrate 90 minutes of load-bearing capacity, integrity and thermal insulation and that, at the same time, certain building materials must at least correspond to reaction-to-fire class A2.

Requirements in Austria

OIB Guideline 2 contains general requirements for reaction to fire in Table 1a. Depending on the building class, different requirements apply to facades, insulation materials, wall and ceiling coverings, floor coverings, installations and other components.

The decisive factor is the classification evidence for the specific product or system. A classification may relate to an individual building material or to a tested overall system. Components of a classified system must therefore not be replaced at will if this changes the proven build-up.

Simulation and evidence

Fire Dynamics Simulator (FDS)

The Fire Dynamics Simulator (FDS) is a CFD program developed by the US National Institute of Standards and Technology for the numerical study of fire-induced flows. It calculates, among other things, temperature, smoke gas and velocity fields, visibility ranges, heat radiation and the effect of ventilation and smoke control measures.

Escape and evacuation simulations

Escape and evacuation simulations use calculation to model the movement of people through a defined system of routes and exits. They are used to determine the required evacuation time (RSET), to identify bottlenecks and to assess variants; a robust conclusion requires traceable occupancy, response and movement parameters.